Cold weather nitrification in lagoons - lagoon nutrient removal such as ammonia.
ARTICLE

The cold reality of nitrification - why aerating may not improve winter lagoon nutrient removal

Installing or increasing aeration in a wastewater lagoon is a common strategy to improve nitrification and ammonia nutrient removal. This upgrade can provide great results in warmer seasons, but as temperatures fall towards freezing, aeration might not be enough to maintain nitrification and produce effluent that complies with discharge standards.

Why aeration alone isn’t enough

On paper, aeration seems like it can help improve nitrification. Ideally, aeration should add 4.6 kg of oxygen for every kg of ammonia to be converted to nitrate and dissolved oxygen should be maintained at about 3 mg/L. But the equation doesn’t account for temperature.

As winter approaches and the temperature of the wastewater declines, so does the rate of nitrification. Nitrifying bacteria are very temperature sensitive so wastewater ammonia removal can experience a significant drop when the water temperature reaches about 15°C and can stop entirely at 5°C or less. At this point, aeration still provides mixing and adds oxygen to the wastewater, but nitrifying bacteria are unlikely to respond to the conditions and no ammonia removal will occur.

Build a better home for nitrifying bacteria

BioCord® Reactors provide a solution. This attached growth system is like a condominium for bacteria that is installed directly into a wastewater lagoon and provides a massive surface area on which cold-tolerant nitrifying bacteria can grow. Once the biofilm is established nitrifying bacteria respond to changes in nutrient loading and maintain nitrification for ammonia removal even when the wastewater temperature is as low as 1°C.

Biocord is a condominium for bacteria

Each BioCord Reactor incorporates an integrated fine-bubble aeration system that provides high oxygen transfer to the biofilm, scours excess biofilm and prevents ice from forming around the BioCord cell. Operational experience in laboratories, pilot systems and permanent installations validates BioCord’s ability to provide robust, resilient cold-weather ammonia removal and dramatically improve the capacity and performance of a wastewater lagoon.

Operators watch as BioCord reactors are lowered into a wastewater lagoon for ammonia removal

BioCord® Reactors - simple, low-energy, lagoon nutrient removal

BioCord Reactors provide a simple, low-energy, fixed-film biological treatment process to dramatically increase the performance of wastewater lagoons and conventional activated sludge systems for ammonia, BOD and TSS removal.

BioCord Reactors can be installed directly into an existing treatment system, which helps to dramatically reduce capital costs by avoiding expansion to the plant footprint or adding side-stream process tanks.

Ready to learn more?

Speak with an expert

Contact us today to discuss a simple, low-energy solution for your site. 

Before You Go....

Keep up to date on the latest projects from Bishop Water.